Voici une liste de messages d'erreur courants provenant de diverses marques. Tous les messages d'erreur ne seront pas listé ici. Il est également conseillé de consulter le manuel de l'appareil.
Brand | Error code | Cause | Action |
---|---|---|---|
______________ | ____________________________ | _________________________ | ________________________________________________________ |
Omnik | Ground I Fault | GFCI failure oversized leakage current | Please check the DC wiring and measure. If you consider the wiring to be in order, contact service onduleur |
Omnik | Fac Failure | Grid frequency failure | Please check the AC wiring and measure. If you consider the wiring to be in order, contact service onduleur |
Omnik | Vac Failure | Grid voltage failure | Please check the AC wiring and measure. If you consider the wiring to be in order, contact service onduleur |
Omnik | Utility Loss | No Utility&Island | Please check the AC wiring and measure. If you consider the wiring to be in order, contact service onduleur |
Omnik | PV Over Voltage | Input voltage too high | Please check the DC wiring and measure. If you consider the wiring to be in order, contact service onduleur |
Omnik | Over Temperature | Temperature abnormal | Check the inverter for heat build up or blockage of the cooler ribs and rectify as required. If this does not correct the problem, contact service onduleur |
Omnik | Isolation Fault | Isolation failure | Check system isolation. If you consider the isolation impedance to be in order, contact service onduleur |
Omnik | Relay-Check Fail | Output relay failure | If problem occurs repeatedly, contact service onduleur |
Omnik | DC INJ High | Output DC injection too high | If problem occurs repeatedly, contact service onduleur |
Omnik | EEPROM R/W Fail | EEPROM problem | If problem occurs repeatedly, contact service onduleur |
Omnik | SCI Failure | Serial communication interface failure | Please contact service onduleur |
Omnik | AC HCT Failure | Output AC sensor abnormal | If problem occurs repeatedly, contact service onduleur |
Omnik | GFCI Failure | GFCI testing device abnormal | If problem occurs repeatedly, contact service onduleur |
Omnik | /W Updating | Update | If problem occurs once only: wait for the regulator to be come stable again. If problem occurs repeatedly: please contact service onduleur |
Omnik | Reconnect s | Reconnect | This text is displayed for information purposes only. |
Omnik | Checking s | Checking | This text is displayed for information purposes only. |
Omnik | Waiting | Initialization & waiting | This text is displayed for information purposes only. |